THIS INSPECTION WAS DONE AS A CONSULTATION PER REQUEST OF RON MAPP OF ST. PAUL'S EPISCOPAL |
CHURCH. ACCORDING TO MR. MAPP, THEY ARE EXPLORING THE IDEA OF BRINGING IN SOMEONE TO OPERATE A |
FOOD SERVICE OPERATION OUT OF THE CHURCH KITCHEN AND POSSIBLY DO SOME CATERING. AT THE TIME OF |
INSPECTION THE FOLLOWING ISSUES WERE IDENTIFIED AND WOULD NEED TO BE CORRECTED. |
|
-NO MOP HOOKS WERE PROVIDED TO HANG MOPS. |
|
-OBSERVED SHELVES MADE OF A BARE UNSEALED WOOD MATERIAL IN DRY STORAGE ROOM. THE WOOD WOULD |
HAVE TO PAINTED OR SEALED WITH A POLYURETHANE SEALANT SO THAT IT IS SMOOTH, NON-ABSORBENT AND |
EASILY CLEANABLE. |
|
-COUNTER TOPS AND WAREWASHING MACHINE AND DRAINBOARDS WERE NOT SEALED TO THE WALL. ALL CLEAN IN |
PLACE EQUIPMENT MUST BE SUFFICIENTLY SPACED OR SEALED TO THE WALL TO FACILITATE CLEANING. |
|
-OBSERVED DOUBLE SINK BUILT INTO DRAINBOARD THAT WOULD LIKELY BE USED FOR FOOD PREPARATION. THE |
SINK WAS WELDED BUT WAS IN GOOD SHAPE. THIS SINKS COULD BE PERMITTED ON A PERFORMANCE BASIS. IF |
THE SINKS COULD NOT BE MAINTAINED CLEAN TO SIGHT AND TOUCH THEY WOULD NEED TO BE REPLACED WITH |
A NON-WELDED FOOD PREP SINK THAT IS NSF APPROVED. |
|
-OBSERVED MISSING COVING THROUGHOUT KITCHEN AND DRY STORAGE AREA. ALL FLOOR AND WALL JUNCTURES |
MUST BE COVED TO FACILITATE CLEANING. |
|
-OBSERVED CONDENSATION BUILDUP ON WALLS AND CEILING NEAR HIGH TEMPERATURE WAREWASHING MACHINE. |
THE CEILING TILE THAT IS DAMAGED FROM THE CONDENSATION MUST BE REPLACED AND WALLS CLEANED TO |
REMOVE RUST STAINS FROM CONDENSATION OR REPAINTED IF STAINS CANNOT BE REMOVED. IF NECESSARY |
MECHANICAL VENTILATION MAY NEED TO BE INSTALLED IF CONDENSATION FROM WAREWASHING MACHINE IS AN |
ISSUE BECOMES A SOURCE OF POTENTIAL CONTAMINATION OF CLEAN EQUIPMENT. ALTERNATIVELY, CONVERTING |
THE WAREWASHING MACHINE FROM A HIGH TEMPERATURE SANITIZING MACHINE TO A CHEMICAL SANITIZING |
MACHINE MAY RESOLVE CONDENSATION ACCUMULATION AND THE NEED FOR MECHANICAL VENTILATION. |
|
-OBSERVED MISSING CUPBOARD DOOR. THE DOOR MAY NEED TO BE REPLACED TO PROTECT CLEAN EQUIPMENT / |
FOOD. |
|
-OBSERVED MISSING, TORN, OR CRACKED FLOOR TILE AROUND FLOOR DRAIN. REPLACE MISSING, TORN, OR |
CRACKED FLOOR TILE AROUND FLOOR DRAIN SO THAT THE FLOOR IS SMOOTH, NON ABSORBENT AND EASILY |
CLEANABLE. |
|
-A DOUBLE DOOR REACH IN COMMERCIAL COOLER AND A SINGLE DOOR UPRIGHT REACH IN FREEZER WAS |
PROVIDED. ADDITIONAL COLD HOLDING AND FREEZER EQUIPMENT MAY NEED TO BE PROVIDED DEPENDING ON |
MENU AND NUMBER OF MEALS SERVED. |
|
THE ABOVE OBSERVATIONS ARE A PRELIMINARY ASSESSMENT OF THE KITCHEN. PRIOR TO OPENING, A MENU, A |
LIST OF EQUIPMENT MAKE AND MODEL NUMBERS AND PLANS OF THE FACILITY MUST BE SUBMITTED FOR PLAN |
REVIEW. ADDITIONALLY, BUILDING AND CODE SHOULD BE CONTACTED TO SCHEDULE A CODE COMPLIANCE |
INSPECTION TO ENSURE THAT THE FACILITY MEETS ALL BUILDING, PLUMBING, ELECTRIC AND FIRE CODES. |
IF PLANS ARE APPROVED AND THE FACILITY MEETS CODE A FINAL WALK THROUGH WILL BE CONDUCTED AND A |
LICENSE APPLICATION WILL BE ISSUED IF THERE ARE NO ISSUES IDENTIFIED. ONCE THE LICENSE |
APPLICATION IS RETURNED WITH THE LICENSE FEE THE FACILITY MAY OPEN FOR BUSINESS. |
|