OBSERVED A RESIDUE BUILDUP IN HANDWASH SINKS IN RESTROOMS ON BOTH SIDES OF THE BUILDING. CLEAN |
ALL HANDWASH SINKS AS OFTEN AS NECESSARY TO MAINTAIN CLEAN TO SIGHT AND TOUCH AND TO ALLOW FOR |
PROPER HANDWASHING. |
|
3717-1-04.5 Equipment, Utensils, and Linens: Cleaning of Equipment and Utensils |
|
(A) Equipment, food-contact surfaces, nonfood-contact surfaces, and utensils. |
|
(1) Equipment food-contact surfaces and utensils shall be clean to sight and touch. |
|
(2) The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and |
other soil accumulations. |
|
(3) Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and |
other debris. |
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
HOT WATER WAS NOT PROVIDED AT HANDWASH SINK IN EMPLOYEE RESTROOM ON WEST SIDE OF BUILDING. |
RESTORE HOT WATER OF AT LEAST 100F TO ALLOW FOR PROPER HANDWASHING. HOT WATER WAS PROVIDED AT |
HANDWASH SINK ON EAST SIDE OF THE BUILDING. |
|
3717-1-05.1 Water, Plumbing, and Waste: Plumbing System |
|
(C) Handwashing sink - installation. |
|
(1) A handwashing sink shall be equipped to provide water at a temperature of at least one hundred degrees |
Fahrenheit (thirty-eight degrees Celsius) through a mixing valve or combination faucet. |
|
(2) A steam mixing valve may not be used at a handwashing sink. |
|
(3) A self-closing, slow-closing, or metering faucet shall provide a flow of water for at least fifteen seconds |
without the need to reactivate the faucet. |
|
(4) An automatic handwashing facility shall be installed in accordance with manufacturer's instructions. |
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
OBSERVED MISSING OR DAMAGED FLOOR TILES. THE STORE HAS BEEN REARRANGED. THE PERSON IN CHARGE |
SAID THAT HE HAS SOMEONE COMING TO REPLACE THE TILES. |
|
ALSO OBSERVED MISSING CEILING TILES IN EMPLOYEE RESTROOM ON EAST SIDE OF THE BUILDING. REPLACE |
MISSING CEILING TILES AS NECESSARY SO THAT THE CEILING IS SMOOTH AND EASILY CLEANABLE. |
|
3717-1-06 Physical Facilities: Materials for Construction and Repair |
|
(A) Indoor areas - surface characteristics |
|
(1) Except as specified in paragraph (A)(2) of this rule, materials for indoor floor, wall, and ceiling surfaces |
under conditions of normal use shall be: |
|
(a) Smooth, durable, and easily cleanable for areas where food service operation or retail food establishment |
activities are conducted; |
|
(b) Closely woven and easily cleanable carpet for carpeted areas; and |
|
(c) Nonabsorbent for areas subject to moisture such as food preparation areas, walk-in refrigerators, |
warewashing areas, toilet rooms, mobile food service operation or mobile retail food establishment servicing areas, |
and areas subject to flushing or spray cleaning methods. |
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
NO PAPER TOWELS WERE PROVIDED AT THE HANDWASH SINK ON THE WEST SIDE OF THE BUILDING. SUPPLY ALL |
HANDWASH SINKS WITH PAPER TOWELS OR OTHER APPROVED MEANS OF HAND DRYING PER RULE REQUIREMENTS |
CITED BELOW. |
|
3717-1-06.2 Physical Facilities: Numbers and Capacities |
|
(C) Handwashing sinks - hand drying provision. |
|
Each handwashing sink or group of adjacent handwashing sinks shall be provided with: |
|
(1) Individual, disposable towels; |
|
(2) A continuous towel system that supplies the user with a clean towel; or |
|
(3) A heated-air hand drying device. |
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
LIGHT IN RESTROOM ON WEST SIDE OF BUILDING WAS NOT WORKING. REPAIR LIGHT TO FACILITATE |
CLEANING. LIGHTING SHOULD BE OF AT LEAST 20 FOOT CANDLE INTENSITY IN RESTROOMS. |
|
3717-1-06.2 Physical Facilities: Numbers and Capacities |
|
(I) Lighting - intensity |
|
The light intensity shall be: |
|
(1) At least ten foot candles (one hundred eight lux) at a distance of thirty inches (seventy-five centimeters) |
above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of |
cleaning; |
|
(2) At least twenty foot candles (two hundred fifteen lux): |
|
(a) At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh |
produce or packaged foods are sold or offered for consumption; |
|
(b) Inside equipment such as reach-in and under-counter refrigerators; and |
|
(c) At a distance of thirty inches (seventy-five centimeters) above the floor in toilet rooms and in areas |
used for handwashing, warewashing, equipment storage, or utensil storage; and |
|
(3) At least fifty foot candles (five hundred forty lux) at a surface where a food employee is working with food, |
utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor. |
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
OBSERVED TWO BOTTLES OF INSECTICIDE AND ROACH AND ANT KILLER STORED IN EMPLOYEE RESTROOM. THESE |
CHEMICALS MAY ONLY BE APPLIED BY A COMMERCIAL LICENSED APPLICATOR. THE ISSUE WAS DISCUSSED WITH |
THE PERSON IN CHARGE AND THE INSECTICIDES WERE DISCARDED. |
|
3717-1-07.1 Poisonous or Toxic Materials: Operational Supplies and Applications |
|
(C) Conditions of use. |
|
Poisonous or toxic materials shall be: |
|
(1) Used according to: |
|
(a) Law and this chapter; |
|
(b) Manufacturer's use directions included in labeling, and, for a pesticide, manufacturer's label instructions |
that state that use is allowed in a food service operation, retail food establishment, or food handling or |
processing areas; |
|
(c) The conditions of licensing, if licensing is required, for use of the pest control materials; and |
|
(d) Additional conditions that may be established by the regulatory authority; and |
|
(2) Applied so that: |
|
(a) A hazard to employees or other persons is not constituted; and |
|
(b) Contamination including toxic residues due to drip, drain, fog, splash or spray on food, equipment, |
utensils, linens, single-service articles, and single-use articles is prevented, and for a restricted-use pesticide, |
this is achieved by: |
|
(i) Removing the items; |
|
(ii) Covering the items with impermeable covers, or |
|
(iii) Taking other appropriate preventive actions, and |
|
(iv) Cleaning and sanitizing equipment and utensils after the application. |
|
(3) A general use pesticide, other than for incidental use after July 1, 2004; or a restricted use pesticide shall |
be applied only by a commercial applicator licensed as specified under section 921.06 of the Revised Code, or a trained |
service person under the direct supervision of the commercial applicator. "Incidental use" means the application of a |
general use pesticide on an occasional, isolated, site-specific basis in order to avoid immediate personal harm. |
"Incidental use" does not mean regular, routine, or maintenance application of a general use pesticide. |
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
NOTE: THE ROOF HAS BEEN REPLACED AND THE CEILING REPAINTED. THERE IS SOME DUST BUILDUP FROM THE |
ROOF AND CEILING REPAIRS THAT WILL NEED CLEANED UP. |
|