Violation: Heavily water stained ceiling tiles observed in the bathroom. Per PIC leak has been fixed. Replace tiles in this |
room with non-absorbant tiles. |
|
|
3717-1-06 Physical facilities: materials for construction and repair. |
(A)Indoor areas - surface characteristics |
(1) Except as specified in paragraph (A)(2) of this rule, materials for indoor floor, wall, and ceiling surfaces |
under conditions of normal use shall be: |
(a) Smooth, durable, and easily cleanable for areas where food service operation or retail food establishment |
activities are conducted; |
(b) Closely woven and easily cleanable carpet for carpeted areas; and |
(c) Nonabsorbent for areas subject to moisture such as food preparation areas, walk-in refrigerators, |
warewashing areas, toilet rooms, mobile food service operation or mobile retail food establishment servicing |
areas, and areas subject to flushing or spray cleaning methods. |
|
|
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
Violation: Warewashing sink has soap and paper towels, handsink is near this sink, supplies are above the warewashing sink. |
Warewashing sinks should not be used and supplied for handwashing. |
|
3717-1-04.4 Equipment, utensils, and linens: maintenance and operation. |
(F)Warewashing sinks - use limitation. |
(1) A warewashing sink may not be used for handwashing as specified under paragraph (D) of rule 3717-1-02.2 |
of the Administrative Code. |
(2) If a warewashing sink is used to wash wiping cloths, wash produce, or thaw food, the sink shall be cleaned |
as specified under paragraph (D) of this rule before and after each time it is used to wash wiping cloths or |
wash produce or thaw food. Sinks used to wash or thaw food shall be sanitized as specified under rule |
3717-1-04.6 of the Administrative Code before and after using the sink to wash produce or thaw food. |
|
|
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
New Turbo Air Freezer in use- model M3F47-2-N is ETL approved. |
|
All cold holding is observed to bbe below 41°F. |
Sanitizer is 300-400 ppm. |
|